-- -- Copyright(C) 2021 Western Telematic, Inc. -- WTI-AFS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, enterprises FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; westernTelematic OBJECT IDENTIFIER ::= { enterprises 2634 } afs MODULE-IDENTITY LAST-UPDATED "202106241600Z" -- 124 Jun 2021 ORGANIZATION "Western Telematic, Inc." CONTACT-INFO "Western Telematic, Inc. 5 Sterling Irvine, Ca 92618 Email: anthonyb@wti.com" DESCRIPTION "This is the MIB module for the AFS" REVISION "202106241600Z" -- 24 Jun 2021 DESCRIPTION "V7.13 for the AFS " ::= { westernTelematic 4 } -- -- System Tables -- systemTables OBJECT IDENTIFIER ::= { afs 100 } -- -- Circuit Table -- circuitTable OBJECT-TYPE SYNTAX SEQUENCE OF CircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of circuits." ::= { systemTables 200 } circuitEntry OBJECT-TYPE SYNTAX CircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the circuit table." INDEX { circuitIndex } ::= { circuitTable 1 } CircuitEntry ::= SEQUENCE { circuitIndex INTEGER, circuitID DisplayString, circuitStatus INTEGER, circuitAction INTEGER, circuitName DisplayString, circuitReason INTEGER } circuitIndex OBJECT-TYPE SYNTAX INTEGER (0..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for the circuit table." ::= { circuitEntry 1 } circuitID OBJECT-TYPE SYNTAX DisplayString(SIZE(9..11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the circuit." ::= { circuitEntry 2 } circuitStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Circuit status" ::= { circuitEntry 3 } circuitAction OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Circuit action" ::= { circuitEntry 4 } circuitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Name of the circuit." ::= { circuitEntry 5 } circuitReason OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Switch reason" ::= { circuitEntry 6 } -- -- Circuit Group Table -- circuitGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF CircuitGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of circuit groups." ::= { systemTables 300 } circuitGroupEntry OBJECT-TYPE SYNTAX CircuitGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the circuit group table." INDEX { circuitGroupIndex } ::= { circuitGroupTable 1 } CircuitGroupEntry ::= SEQUENCE { circuitGroupIndex INTEGER, circuitGroupName DisplayString, circuitGroupAction INTEGER } circuitGroupIndex OBJECT-TYPE SYNTAX INTEGER (0..54) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for the circuit group table." ::= { circuitGroupEntry 1 } circuitGroupName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..24)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the circuit group." ::= { circuitGroupEntry 2 } circuitGroupAction OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Circuit group action" ::= { circuitGroupEntry 3 } -- -- User Table -- userTable OBJECT-TYPE SYNTAX SEQUENCE OF UserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of users." ::= { systemTables 400 } userEntry OBJECT-TYPE SYNTAX UserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the user table." INDEX { userIndex } ::= { userTable 1 } UserEntry ::= SEQUENCE { userIndex INTEGER, userName DisplayString, userPasswd DisplayString, userAccessLevel INTEGER, userPortAccess DisplayString, userCircuitAccess DisplayString, userGroupAccess DisplayString, userSerialAccess INTEGER, userTelnetSshAccess INTEGER, userWebAccess INTEGER, userOutboundTelAccess INTEGER, userCurrentPowerMetering INTEGER, userCallbackNum1 DisplayString, userCallbackNum2 DisplayString, userCallbackNum3 DisplayString, userCallbackNum4 DisplayString, userCallbackNum5 DisplayString, userSubmit INTEGER } userIndex OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for the user table." ::= { userEntry 1 } userName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the user." ::= { userEntry 2 } userPasswd OBJECT-TYPE SYNTAX DisplayString(SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The password of the user." ::= { userEntry 3 } userAccessLevel OBJECT-TYPE SYNTAX INTEGER (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Users access level" ::= { userEntry 4 } userPortAccess OBJECT-TYPE SYNTAX DisplayString(SIZE(1..5)) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to ports." ::= { userEntry 5 } userCircuitAccess OBJECT-TYPE SYNTAX DisplayString(SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to circuits." ::= { userEntry 6 } userGroupAccess OBJECT-TYPE SYNTAX DisplayString(SIZE(1..54)) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to circuit groups." ::= { userEntry 10 } userSerialAccess OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to serial interface." ::= { userEntry 11 } userTelnetSshAccess OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to Telnet/SSH interface." ::= { userEntry 12 } userWebAccess OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to web interface." ::= { userEntry 13 } userOutboundTelAccess OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to outbound telnet." ::= { userEntry 14 } userCurrentPowerMetering OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Access to Current/Power Metering." ::= { userEntry 15 } userCallbackNum1 OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Callback number1." ::= { userEntry 16 } userCallbackNum2 OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Callback number2." ::= { userEntry 17 } userCallbackNum3 OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Callback number3." ::= { userEntry 18 } userCallbackNum4 OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Callback number4." ::= { userEntry 19 } userCallbackNum5 OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Callback number5." ::= { userEntry 20 } userSubmit OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Submit changes to user." ::= { userEntry 31 } -- -- Environment Tables -- environmentTables OBJECT IDENTIFIER ::= { afs 200 } environmentUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvironmentUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of environment status for units." ::= { environmentTables 10 } environmentUnitEntry OBJECT-TYPE SYNTAX EnvironmentUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the environment unit table." INDEX { environmentUnitIndex } ::= { environmentUnitTable 1 } EnvironmentUnitEntry ::= SEQUENCE { environmentUnitIndex INTEGER, environmentUnitName DisplayString, environmentUnitTemperature INTEGER, environmentUnitMonitorAlarm INTEGER, environmentSysRAM INTEGER, environmentSysFlash INTEGER, environmentMacEth0 DisplayString, environmentMacEth1 DisplayString, environmentInputPower1 INTEGER, environmentInputPower2 INTEGER, environmentInputPower3 INTEGER, environmentInputPower4 INTEGER, environmentModemPhoneNumber DisplayString, environmentSerialNumber DisplayString, environmentSoftwareVersion DisplayString, environmentAssetTag DisplayString, environmentSiteId DisplayString } environmentUnitIndex OBJECT-TYPE SYNTAX INTEGER (0..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for the environment unit table." ::= { environmentUnitEntry 1 } environmentUnitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the unit." ::= { environmentUnitEntry 2 } environmentUnitTemperature OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of the unit." ::= { environmentUnitEntry 3 } environmentUnitMonitorAlarm OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Monitor alarm status, 0 = LOW, 1 = HIGH" ::= { environmentUnitEntry 17 } environmentSysRAM OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Total system RAM." ::= { environmentUnitEntry 18 } environmentSysFlash OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Total system Flash." ::= { environmentUnitEntry 19 } environmentMacEth0 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MAC Address Eth0" ::= { environmentUnitEntry 20 } environmentMacEth1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MAC Address Eth1" ::= { environmentUnitEntry 21 } environmentInputPower1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Status of first power input." ::= { environmentUnitEntry 22 } environmentInputPower2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Status of second power input." ::= { environmentUnitEntry 23 } environmentInputPower3 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Status of third power input." ::= { environmentUnitEntry 24 } environmentInputPower4 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Status of fourth power input." ::= { environmentUnitEntry 25 } environmentModemPhoneNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit modem phone number" ::= { environmentUnitEntry 26 } environmentSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit serial number" ::= { environmentUnitEntry 27 } environmentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit software version" ::= { environmentUnitEntry 28 } environmentAssetTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit asset tag" ::= { environmentUnitEntry 29 } environmentSiteId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit site ID" ::= { environmentUnitEntry 30 } environmentSystemTotalCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Total current for system (In tenths of amps, divide by 10 for value in amps)." ::= { environmentTables 60 } environmentSystemTotalPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Total power on system." ::= { environmentTables 70 } environmentMonthlyPowerLog OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly power usage log" ::= { environmentTables 80 } -- -- Alarm Tables -- alarmTables OBJECT IDENTIFIER ::= { afs 280 } alarmOverTemperatureInitial OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Over Temperature Initial Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 3 } alarmOverTemperatureCritical OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Over Temperature Critical Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 4 } alarmPingNoAnswer OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Ping No Answer Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 8 } alarmInvalidAccessLockout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Invalid Access Lockout Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 9 } alarmPowerCycle OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Power Cycle Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 10 } alarmMonitor OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Monitor Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 12 } alarmNoDialtone OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the No Dialtone Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 16 } alarmWakeupOnFailure OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Wakeup On Failure Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 17 } alarmIpPassthroughDataUsage OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the IP Passthrough Data Usage Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 18 } alarmBufferFiltering OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Buffer Filtering Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 19 } alarmNoCellularPppConnection OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "State of the No Cellular PPP Connection Alarm (0 = Inactive, 1 = Active)" ::= { alarmTables 20 } -- -- Traps -- wtiTraps OBJECT IDENTIFIER ::= { afs 300 } -- Trap Info trapInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm information" ::= { wtiTraps 1 } -- Test Traps testTraps OBJECT IDENTIFIER ::= { wtiTraps 2} testTrap TRAP-TYPE ENTERPRISE testTraps VARIABLES { trapInfo } DESCRIPTION "A test trap" ::= 1 -- Alarm Traps overTemperatureInitialTraps OBJECT IDENTIFIER ::= { wtiTraps 6} overTemperatureInitialSetTrap TRAP-TYPE ENTERPRISE overTemperatureInitialTraps VARIABLES { trapInfo } DESCRIPTION "Over Temperature Initial Alarm" ::= 1 overTemperatureInitialClearTrap TRAP-TYPE ENTERPRISE overTemperatureInitialTraps VARIABLES { trapInfo } DESCRIPTION "Over Temperature Initial Alarm (Clear)" ::= 2 overTemperatureCriticalTraps OBJECT IDENTIFIER ::= { wtiTraps 7} overTemperatureCriticalSetTrap TRAP-TYPE ENTERPRISE overTemperatureCriticalTraps VARIABLES { trapInfo } DESCRIPTION "Over Temperature Critical Alarm" ::= 1 overTemperatureCriticalClearTrap TRAP-TYPE ENTERPRISE overTemperatureCriticalTraps VARIABLES { trapInfo } DESCRIPTION "Over Temperature Critical Alarm (Clear)" ::= 2 pingNoAnswerTraps OBJECT IDENTIFIER ::= { wtiTraps 11} pingNoAnswerSetTrap TRAP-TYPE ENTERPRISE pingNoAnswerTraps VARIABLES { trapInfo } DESCRIPTION "Ping No Answer" ::= 1 pingNoAnswerClearTrap TRAP-TYPE ENTERPRISE pingNoAnswerTraps VARIABLES { trapInfo } DESCRIPTION "Ping No Answer (Clear)" ::= 2 lockoutTraps OBJECT IDENTIFIER ::= { wtiTraps 12} lockoutSetTrap TRAP-TYPE ENTERPRISE lockoutTraps VARIABLES { trapInfo } DESCRIPTION "Invalid Access Lockout" ::= 1 lockoutClearTrap TRAP-TYPE ENTERPRISE lockoutTraps VARIABLES { trapInfo } DESCRIPTION "Invalid Access Lockout (Clear)" ::= 2 powercycleTraps OBJECT IDENTIFIER ::= { wtiTraps 13} powercycleSetTrap TRAP-TYPE ENTERPRISE powercycleTraps VARIABLES { trapInfo } DESCRIPTION "Power Cycle" ::= 1 monitorAlarmTraps OBJECT IDENTIFIER ::= { wtiTraps 14} monitorAlarmSetTrap TRAP-TYPE ENTERPRISE monitorAlarmTraps VARIABLES { trapInfo } DESCRIPTION "Monitor Alarm" ::= 1 monitorAlarmClearTrap TRAP-TYPE ENTERPRISE monitorAlarmTraps VARIABLES { trapInfo } DESCRIPTION "Monitor Alarm (Clear)" ::= 2 noDialtoneTraps OBJECT IDENTIFIER ::= { wtiTraps 18} noDialtoneSetTrap TRAP-TYPE ENTERPRISE noDialtoneTraps VARIABLES { trapInfo } DESCRIPTION "No Dialtone" ::= 1 noDialtoneClearTrap TRAP-TYPE ENTERPRISE noDialtoneTraps VARIABLES { trapInfo } DESCRIPTION "No Dialtone (Clear)" ::= 2 wakeupOnFailureTraps OBJECT IDENTIFIER ::= { wtiTraps 19} wakeupOnFailureSetTrap TRAP-TYPE ENTERPRISE wakeupOnFailureTraps VARIABLES { trapInfo } DESCRIPTION "Wakeup On Failure" ::= 1 wakeupOnFailureClearTrap TRAP-TYPE ENTERPRISE wakeupOnFailureTraps VARIABLES { trapInfo } DESCRIPTION "Wakeup On Failure (Clear)" ::= 2 ipPassthroughDataUsageTraps OBJECT IDENTIFIER ::= { wtiTraps 20} ipPassthroughDataUsageSetTrap TRAP-TYPE ENTERPRISE ipPassthroughDataUsageTraps VARIABLES { trapInfo } DESCRIPTION "IP Passthrough Data Usage" ::= 1 ipPassthroughDataUsageClearTrap TRAP-TYPE ENTERPRISE ipPassthroughDataUsageTraps VARIABLES { trapInfo } DESCRIPTION "IP Passthrough Data Usage (Clear)" ::= 2 bufferFilteringTraps OBJECT IDENTIFIER ::= { wtiTraps 21} bufferFilteringSetTrap TRAP-TYPE ENTERPRISE bufferFilteringTraps VARIABLES { trapInfo } DESCRIPTION "Buffer Filtering" ::= 1 bufferFilteringClearTrap TRAP-TYPE ENTERPRISE bufferFilteringTraps VARIABLES { trapInfo } DESCRIPTION "Buffer Filtering (Clear)" ::= 2 noCellularPppConnectionTraps OBJECT IDENTIFIER ::= { wtiTraps 22} noCellularPppConnectionSetTrap TRAP-TYPE ENTERPRISE noCellularPppConnectionTraps VARIABLES { trapInfo } DESCRIPTION "No Cellular PPP Connection" ::= 1 noCellularPppConnectionClearTrap TRAP-TYPE ENTERPRISE noCellularPppConnectionTraps VARIABLES { trapInfo } DESCRIPTION "No Cellular PPP Connection (Clear)" ::= 2 END